Print Back
4 Way / 3 Position 1/4" NPT Double Air Pilot Operated

TECHNICAL DATA:

Port Sizes: 1/4" NPT
Working Pressure: Vacuum service to 150 PSI
Pilot Pressure:
    22 PSI minimum - Double Solenoid & Double Air Pilot (2 position models)
    45 PSI minimum - Single Solenoid & Single Air Pilot
    45 PSI minimum - Double Solenoid & Double Air Pilot (3 position models)
    Dual pressure applications acceptable when external pilot supply is used.
Flow: Cv 1.1
Temperature Range:
    Solenoid Valve +5ºF to +120ºF
    Air Pilot -20ºF to + 175ºF
    Explosion Proof Solenoid: 0º to +150ºF
Media: Air (either lubricated or non-lubricated)
Seals: Buna-N
Manual Override: Locking

For all applications when supply pressure is 45 psi or higher. Use external pilot version if supply pressure is under 45 psi (including vacuum or dual pressure applications). Take care to note which version is required before ordering since internal/external conversion is not field convertible.

All Standard valves are rated for NEMA 4. Brad Harrison® coils available - consult factory.
Aventics CD07 Double Air Pilot Valves (4-Way/3 Position)
Aventics CD07 Double Air Pilot Valves (4-Way/3 Position)-2
Unit of Measure
Items Aventics CD07 Double Air Pilot Valves (4-Way/3 Position)
R432016612
Rexroth CD07 Double Air Pilot Valves (4-Way/3 Position)
Aventics CD07 Double Air Pilot Valves (4-Way/3 Position)
R432016619
Rexroth CD07 Double Air Pilot Valves (4-Way/3 Position)
Aventics CD07 Double Air Pilot Valves (4-Way/3 Position)
R432016620
Rexroth CD07 Double Air Pilot Valves (4-Way/3 Position)
Old Part # N/A PS 034010-3535 PS 34010-3535 PS-034010-03535 PS034010-3535 PS34010-3535 N/A PS 034020-3535 PS 34020-3535 PS-034020-03535 PS034020-3535 PS34020-3535 N/A PS 034030-3535 PS 34030-3535 PS-034030-03535 PS034030-3535 PS34030-3535
Center N/A Closed N/A Exhaust Open N/A Supply Open
Port Size N/A 1/4" NPT
Working Pressure N/A Vacuum service to 150 PSI
Flow N/A Cv
Temperature Range (Air Pilot) N/A -20 to +175 ºF
Media N/A Air (either lubricated or non-lubricated)
Seals N/A Buna-N
Manual Override N/A Locking
Electrical Data N/A
Standard Voltage
(all coils are rated for continues duty)
Power Consumption
Inrush Holding
110 VAC 50 Hz/120 VAC 60 Hz
24 VAC 50/60 Hz
6.4 VA 3.7 VA
12, 24 VDC 2.7 W

Voltage Tolerance: ±10%
NOTE: Electrical connectors must be ordered separately.
One per solenoid required, see Solenoid Connectors page.
Features N/A
  • The 1/4” 4-way, 5-ported CD07 Valve is an extremely versatile, yet compact, design. This low-profile spool type design will not only enhance the appearance of your equipment, but will save valuable engineering space. A new simplified internal design allows for consistently reliable performance and ease of operation.

  • The CD07 Valve is available with a wide range of solenoid, air pilot and mechanical operators. This new design allows each valve body to be readily STACKED through a convenient and simplified single pressure port bar. Unique optional solenoid connectors offer neon indicator lights for (AC) circuits and L.E.D. displays for (DC) circuits.

  • Standard Plug-In DIN Connection "Low wattage" (2.1W) solenoid and connector, available with or without built-in indicator light.

  • External Pilot: (not shown) Allows an independent air supply to be connected to the pilot port of the solenoid operator.

  • Manual Locking Overrides: Allow supplementary manual control and permit operating the valve when the electric power is off.

  • Solenoid Coil Removal: Un-screw coil retaining nut and slip off the coil.

  • Seal Spacers: New lightweight acetal cartridge assembly.

  • Manifold System: Common pressure port bar