Catalog
Rexroth Series 740 Manifolds and Gang Stacking
Aventics Series 740 Valves
4 Way / 2 and 3 Position Manifold Mounts & Gang Stacking
TECHNICAL DATA:
Port Sizes:
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking
Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page.
Recommended Tubing:
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.
SHEAR PLUG KNOCKOUT
Ganged assembly-common supply pressure obtainable by knockout shear plugs.
Stack can be held together and mounted with readily available 1/8" "all thread" material.
MANIFOLD INSTALLATION NOTE:
The first and last segment should always be securely mounted to a plate. If more than five valves are used, every third valve segment should also be securely mounted.
Ordering Example
(4 Station Manifold)
1 - Inlet Segment
1 - End Segment
2 - Station Segment
TECHNICAL DATA:
Port Sizes:
- Integrated Fittings for 3/8", 5/16", and 8mm tubing
Push-in fitting styles bodies available for metric tubing only (2 position only)
- 20 PSI minimum
150 PSI maximum
External Pilots not available
- Cv=0.7 - with Integrated Fittings
(Cv=1.3 - comparable flow to threaded part valve)
- Solenoid Valve +5°F to 122°F
Air Pilot +5°F to 140°F
Materials: Polyacetal Engineering plastic with Buna N seals and diaphragms
Combination Manual Override: Locking & Non-Locking
Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page.
Recommended Tubing:
- Standard 3/8" O.D> x 0.062" wall - poly tubing
5/16" O.D. x 0.040 wall - nylon tubing
8mm x 1.00mm wall poly tubing
Valves designed for 10mm O.D. x 1mm wall poly tubing are also available.
Adapters available: 1/4" O.D. x 0.040 wall - poly tubing.
Tube nuts are supplied with each valve for 3/8" x 0.062 wall poly tubing.
SHEAR PLUG KNOCKOUT
Ganged assembly-common supply pressure obtainable by knockout shear plugs.
Stack can be held together and mounted with readily available 1/8" "all thread" material.
MANIFOLD INSTALLATION NOTE:
The first and last segment should always be securely mounted to a plate. If more than five valves are used, every third valve segment should also be securely mounted.
Ordering Example
(4 Station Manifold)
1 - Inlet Segment
1 - End Segment
2 - Station Segment
Item # |
Old Part # |
Description |
Add To Cart/Request Quote |
---|---|---|---|
R432013811 R432013811/Asset/a1589.jpg | Old Part # N/A P -067701-00000 | Description N/A Inlet Segment |
Add To Cart
Request Quote |
R432013812 R432013812/Asset/a1589.jpg | Old Part # N/A P -067702-00000 | Description N/A End Segment |
Add To Cart
Request Quote |
R432013813 R432013813/Asset/a1589.jpg | Old Part # N/A P -067703-00000 | Description N/A Station Segment |
Add To Cart
Request Quote |
R432015880 R432015880/Asset/a1589.jpg | Old Part # N/A P -069881-00000 | Description N/A Single Subbase (Identical to inlet segment except rear cavities are blocked. Used to manifold mount one valve only. |
Add To Cart
Request Quote |